Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.876
Filtrar
2.
Ann Card Anaesth ; 27(2): 162-164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38607881

RESUMO

ABSTRACT: We report a case of simultaneous transcatheter aortic valve replacement and endovascular aneurysm repair. Our aim was to advocate the role of local and regional anesthesia as a key contributor in maintaining hemodynamic stability and avoiding abrupt blood pressure change. Endovascular combined procedures are gaining popularity for their numerous advantages. Nevertheless, they carry significant risks for their hemodynamic implications. It is imperative to acknowledge the modifications occurring after each correction and act accordingly. Different anesthesia approaches can dramatically influence hemodynamics; among all, we found local and regional anesthesia would better serve this objective.


Assuntos
Anestesia por Condução , Anestésicos , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Humanos , Aneurisma da Aorta Abdominal/cirurgia
3.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579061

RESUMO

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Masculino , Humanos , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Axila/cirurgia , Perna (Membro)/cirurgia , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento , Aneurisma Ilíaco/cirurgia
4.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612791

RESUMO

Neutrophil extracellular traps (NETs), composed of DNA, histones, and antimicrobial proteins, are released by neutrophils in response to pathogens but are also recognized for their involvement in a range of pathological processes, including autoimmune diseases, cancer, and cardiovascular diseases. This review explores the intricate roles of NETs in different cardiovascular conditions such as thrombosis, atherosclerosis, myocardial infarction, COVID-19, and particularly in the pathogenesis of abdominal aortic aneurysms. We elucidate the mechanisms underlying NET formation and function, provide a foundational understanding of their biological significance, and highlight the contribution of NETs to inflammation, thrombosis, and tissue remodeling in vascular disease. Therapeutic strategies for preventing NET release are compared with approaches targeting components of formed NETs in cardiovascular disease. Current limitations and potential avenues for clinical translation of anti-NET treatments are discussed.


Assuntos
Aneurisma da Aorta Abdominal , Sistema Cardiovascular , Armadilhas Extracelulares , Infarto do Miocárdio , Trombose , Humanos
5.
J Cardiothorac Surg ; 19(1): 199, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600502

RESUMO

BACKGROUND: Total endovascular technique with fenestrated endovascular graft might be hampered for the late dilatation of proximal landing zone, which may cause endografts migration. We describe a successful urgent hybrid procedure for extent III thoracoabdominal aortic aneurysm with aortic intramural hematoma. CASE PRESENTATION: A 55-year-old female with thoracoabdominal aortic aneurysm was considered at high surgical risk and unfit for open repair due to multiple comorbidities. Therefore, a hybrid procedure of surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted Transaortic epicardial fixation of endograft was finally chosen and performed in the endovascular operating room. A 3-port technique was performed through a left video-assisted thoracoscopic approach. After the first tampering stent-graft was deployed, a double-needle suture was penetrated both the aortic wall and stent-graft to fixate it in the proximal descending aorta. Then the second endograft, which had been fenestrated on table, was introduced and oriented extracorporeally by rotating superior mesenteric artery and left renal artery fenestration radiopaque markers and deployed with perfect apposition between the fenestrations and target visceral artery. Each vessel was sequentially stented using Viabahn self-expandable stent to finish target vessel stenting. An Ankura cuff stent was deployed in the distal abdominal aortic artery. CONCLUSION: Surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted fixation may be an innovative and viable alternative for selected high-risk patients with extent III thoracoabdominal aortic aneurysm. A longer follow-up is needed to ascertain the success of this approach.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Cirurgiões , Feminino , Humanos , Pessoa de Meia-Idade , Prótese Vascular , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Toracoscópios , Resultado do Tratamento , Stents , Procedimentos Endovasculares/métodos , Desenho de Prótese , Aneurisma da Aorta Abdominal/cirurgia
6.
J R Soc Interface ; 21(213): 20230656, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593843

RESUMO

Peripheral arterial disease (PAD) and abdominal aortic aneurysms (AAAs) often coexist and pose significant risks of mortality, yet their mutual interactions remain largely unexplored. Here, we introduce a fluid mechanics model designed to simulate the haemodynamic impact of PAD on AAA-associated risk factors. Our focus lies on quantifying the uncertainty inherent in controlling the flow rates within PAD-affected vessels and predicting AAA risk factors derived from wall shear stress. We perform a sensitivity analysis on nine critical model parameters through simulations of three-dimensional blood flow within a comprehensive arterial geometry. Our results show effective control of the flow rates using two-element Windkessel models, although specific outlets need attention. Quantities of interest like endothelial cell activation potential (ECAP) and relative residence time are instructive for identifying high-risk regions, with ECAP showing greater reliability and adaptability. Our analysis reveals that the uncertainty in the quantities of interest is 187% of that of the input parameters. Notably, parameters governing the amplitude and frequency of the inlet velocity exert the strongest influence on the risk factors' variability and warrant precise determination. This study forms the foundation for patient-specific simulations involving PAD and AAAs which should ultimately improve patient outcomes and reduce associated mortality rates.


Assuntos
Aneurisma da Aorta Abdominal , Doença Arterial Periférica , Humanos , Reprodutibilidade dos Testes , Incerteza , Modelos Cardiovasculares , Hemodinâmica , Estresse Mecânico
7.
BMJ Open ; 14(4): e081046, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38626979

RESUMO

INTRODUCTION: Incisional hernia (IH) is a prevalent and potentially dangerous complication of abdominal surgery, especially in high-risk groups. Mesh reinforcement of the abdominal wall has been studied as a potential intervention to prevent IHs. Randomised controlled trials (RCTs) have demonstrated that prophylactic mesh reinforcement after abdominal surgery, in general, is effective and safe. In patients with abdominal aortic aneurysm (AAA), prophylactic mesh reinforcement after open repair has not yet been recommended in official guidelines, because of relatively small sample sizes in individual trials. Furthermore, the identification of subgroups that benefit most from prophylactic mesh placement requires larger patient numbers. Our primary aim is to evaluate the efficacy and effectiveness of the use of a prophylactic mesh after open AAA surgery to prevent IH by performing an individual patient data meta-analysis (IPDMA). Secondary aims include the evaluation of postoperative complications, pain and quality of life, and the identification of potential subgroups that benefit most from prophylactic mesh reinforcement. METHODS AND ANALYSIS: We will conduct a systematic review to identify RCTs that study prophylactic mesh placement after open AAA surgery. Cochrane Central Register of Controlled Trials, MEDLINE Ovid, Embase, Web of Science Core Collection and Google Scholar will be searched from the date of inception onwards. RCTs must directly compare primary sutured closure with mesh closure in adult patients who undergo open AAA surgery. Lead authors of eligible studies will be asked to share individual participant data (IPD). The risk of bias (ROB) for each included study will be assessed using the Cochrane ROB tool. An IPDMA will be performed to evaluate the efficacy, with the IH rate as the primary outcome. Any signs of heterogeneity will be evaluated by Forest plots. Time-to-event analyses are performed using Cox regression analysis to evaluate risk factors. ETHICS AND DISSEMINATION: No new data will be collected in this study. We will adhere to institutional, national and international regulations regarding the secure and confidential sharing of IPD, addressing ethics as indicated. We will disseminate findings via international conferences, open-source publications in peer-reviewed journals and summaries posted online. PROSPERO REGISTRATION NUMBER: CRD42022347881.


Assuntos
Aneurisma da Aorta Abdominal , Hérnia Incisional , Adulto , Humanos , Hérnia Incisional/prevenção & controle , Hérnia Incisional/cirurgia , Telas Cirúrgicas , Complicações Pós-Operatórias/etiologia , Laparotomia/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Revisões Sistemáticas como Assunto , Metanálise como Assunto
8.
Sci Rep ; 14(1): 8924, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637613

RESUMO

Accurate measurement of abdominal aortic aneurysm is essential for selecting suitable stent-grafts to avoid complications of endovascular aneurysm repair. However, the conventional image-based measurements are inaccurate and time-consuming. We introduce the automated workflow including semantic segmentation with active learning (AL) and measurement using an application programming interface of computer-aided design. 300 patients underwent CT scans, and semantic segmentation for aorta, thrombus, calcification, and vessels was performed in 60-300 cases with AL across five stages using UNETR, SwinUNETR, and nnU-Net consisted of 2D, 3D U-Net, 2D-3D U-Net ensemble, and cascaded 3D U-Net. 7 clinical landmarks were automatically measured for 96 patients. In AL stage 5, 3D U-Net achieved the highest dice similarity coefficient (DSC) with statistically significant differences (p < 0.01) except from the 2D-3D U-Net ensemble and cascade 3D U-Net. SwinUNETR excelled in 95% Hausdorff distance (HD95) with significant differences (p < 0.01) except from UNETR and 3D U-Net. DSC of aorta and calcification were saturated at stage 1 and 4, whereas thrombus and vessels were continuously improved at stage 5. The segmentation time between the manual and AL-corrected segmentation using the best model (3D U-Net) was reduced to 9.51 ± 1.02, 2.09 ± 1.06, 1.07 ± 1.10, and 1.07 ± 0.97 min for the aorta, thrombus, calcification, and vessels, respectively (p < 0.001). All measurement and tortuosity ratio measured - 1.71 ± 6.53 mm and - 0.15 ± 0.25. We developed an automated workflow with semantic segmentation and measurement, demonstrating its efficiency compared to conventional methods.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Calcinose , Procedimentos Endovasculares , Trombose , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aprendizagem Baseada em Problemas , Semântica , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador
9.
Int J Biol Sci ; 20(6): 2092-2110, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38617538

RESUMO

Development of non-surgical treatment of human abdominal aortic aneurysm (AAA) has clinical significance. Colchicine emerges as an effective therapeutic regimen in cardiovascular diseases. Yet, whether colchicine slows AAA growth remain controversy. Here, we demonstrated that daily intragastric administration of low-dose colchicine blocked AAA formation, prevented vascular smooth muscle cell (SMC) phenotype switching and apoptosis, and vascular inflammation in both peri-aortic CaPO4 injury and subcutaneous angiotensin-II infusion induced experimental AAA mice models. Mechanistically, colchicine increased global mRNA stability by inhibiting the METTL14/YTHDC1-mediated m6A modification, resulting in increased sclerostin (SOST) expression and consequent inactivation of the WNT/ß-catenin signaling pathway in vascular SMCs from mouse AAA lesions and in cultured human aortic SMCs. Moreover, human and mouse AAA lesions all showed increased m6A methylation, decreased SOST expression, and skewed synthetic SMC de-differentiation phenotype, compared to those without AAA. This study uncovers a novel mechanism of colchicine in slowing AAA development by using the METTL14/SOST/WNT/ß-catenin axis to control vascular SMC homeostasis in mouse aortic vessels and in human aortic SMCs. Therefore, use of colchicine may benefit AAA patients in clinical practice.


Assuntos
Aneurisma da Aorta Abdominal , Músculo Liso Vascular , Humanos , Animais , Camundongos , Aneurisma da Aorta Abdominal/tratamento farmacológico , Homeostase , Aorta , Colchicina/uso terapêutico
10.
Cell Mol Life Sci ; 81(1): 175, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597937

RESUMO

Phenotypic transformation of vascular smooth muscle cells (VSMCs) plays a crucial role in abdominal aortic aneurysm (AAA) formation. CARMN, a highly conserved, VSMC-enriched long noncoding RNA (lncRNA), is integral in orchestrating various vascular pathologies by modulating the phenotypic dynamics of VSMCs. The influence of CARMN on AAA formation, particularly its mechanisms, remains enigmatic. Our research, employing single-cell and bulk RNA sequencing, has uncovered a significant suppression of CARMN in AAA specimens, which correlates strongly with the contractile function of VSMCs. This reduced expression of CARMN was consistent in both 7- and 14-day porcine pancreatic elastase (PPE)-induced mouse models of AAA and in human clinical cases. Functional analyses disclosed that the diminution of CARMN exacerbated PPE-precipitated AAA formation, whereas its augmentation conferred protection against such formation. Mechanistically, we found CARMN's capacity to bind with SRF, thereby amplifying its role in driving the transcription of VSMC marker genes. In addition, our findings indicate an enhancement in CAMRN transcription, facilitated by the binding of NRF2 to its promoter region. Our study indicated that CARMN plays a protective role in preventing AAA formation and restrains the phenotypic transformation of VSMC through its interaction with SRF. Additionally, we observed that the expression of CARMN is augmented by NRF2 binding to its promoter region. These findings suggest the potential of CARMN as a viable therapeutic target in the treatment of AAA.


Assuntos
Aneurisma da Aorta Abdominal , RNA Longo não Codificante , Humanos , Camundongos , Animais , Suínos , RNA Longo não Codificante/genética , Músculo Liso Vascular , Fator 2 Relacionado a NF-E2/genética , Aneurisma da Aorta Abdominal/induzido quimicamente , Aneurisma da Aorta Abdominal/genética , Modelos Animais de Doenças
11.
Angiol. (Barcelona) ; 76(2): 67-82, Mar-Abr. 2024. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-232380

RESUMO

Introducción: una estrategia para reducir la mortalidad de los aneurismas de la aorta abdominal es conocer su existencia en fase asintomática. Así podremos clasificar los pacientes, en función del tamaño del aneurisma, en candidatos a cirugía programada o a seguimiento periódico. Objetivos: conocer la eficacia, la seguridad y la aceptabilidad de un programa piloto de cribado de aneurismas de la aorta abdominal mediante ecografía abdominal realizada en una población de riesgo. Material y métodos: programa organizado por la Real Academia de Medicina y el Instituto de Investigación Biomédica y ejecutado por el Servicio de Angiología, Cirugía Vascular y Endovascular del Hospital Universitario de Salamanca. El cribado se realizó hace un año, en dos carpas situadas en una céntrica plaza de Salamanca. El análisis incluyó a 295 varones ≥ 65 años, residentes en Salamanca capital, de forma libre y gratuita. Se excluyeron aquellos con aneurisma aórtico conocido. Se realizaron: 1) registro de datos; 2) eco Doppler color por especialistas en angiología y cirugía vascular, y 3) encuesta de satisfacción. Todos firmaron un consentimiento informado. Resultados: el diámetro transversal medio de la aorta abdominal fue de 1,81 ± 0,36 cm. Se detectaron 2 aneurismas (diámetro mayor: ≥ 3,0 cm; 3,1 y 4,7 cm) y 3 ectasias aórticas (diámetro ≥ 2,5 y < 3,0 cm). El 98,3 % (290 varones) no presentó ectasia o aneurisma (aorta < 2,5 cm). Tres individuos (obesidad o aire intrabdominal) fueron reevaluados posteriormente. Se analizaron los factores de riesgo y los antecedentes de la población cribada. 180 participantes del cribado (61,0 %) rellenaron anónimamente una encuesta de satisfacción, con resultados muy positivos. Conclusión: si bien el rendimiento de detección fue bajo, la estrategia y el método empleado fueron satisfactorios para el equipo explorador y la población explorada. Este estudio piloto nos permitirá planificar y organizar un segundo cribado más amplio y de nuevos objetivos.(AU)


Introduction: a strategy to reduce the mortality of abdominal aortic aneurysms is to know their existence in theasymptomatic phase. This way we can classify patients, mainly according to the size of the aneurysm, into candi-dates for scheduled elective surgery or periodic follow-up.Objectives: to determine the effectiveness, safety, and acceptability of a pilot screening program for abdominalaortic aneurysms, using abdominal ultrasound, performed in a risk population.Material and methods: program organized by the Royal Academy of Medicine and the Biomedical ResearchInstitute, and carried out by the Angiology and Vascular Surgery service of the University Hospital of Salamanca.The screening was carried out a year ago, in two tents located in a central square in Salamanca. The study included295 men over 65 years of age, residents of Salamanca capital, free of charge. Those with known aortic aneurysmwere excluded. The following were carried out: 1) data recording; 2) color echo-Doppler, by specialists in angiologyand vascular surgery; and 3) satisfaction survey. All signed an informed consent.Results: the mean transverse diameter of the abdominal aorta was 1.81 ± 0.36 cm. Two aneurysms were detect-ed (largest diameter ≥ 3.0 cm; 3.1 and 4.7 cm), and 3 aortic ectasias (diameter ≥ 2.5 and < 3.0 cm). The 98.3 %(290 men) did not present ectasia or aneurysm (aorta < 2.5 cm). Three individuals (obesity or intra-abdominal air) weresubsequently re-evaluated. The risk factors and background of the screened population were analyzed. A satisfactionsurvey was completed freely and anonymously by 180 screening participants (61.0 %) with very positive results.Conclusion: although the detection performance was low, the strategy and method used were satisfactory for theexploring team and the population explored. The present pilot study will allow us to plan and organize a second,broader screening with new objectives.(AU)


Assuntos
Humanos , Masculino , Feminino , Aneurisma da Aorta Abdominal , Programas de Rastreamento , Aorta Abdominal/cirurgia , Sistema Cardiovascular , Espanha , Procedimentos Cirúrgicos Cardiovasculares , Projetos Piloto
12.
Trials ; 25(1): 214, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528619

RESUMO

BACKGROUND: Endovascular repair of aortic aneurysmal disease is established due to perceived advantages in patient survival, reduced postoperative complications, and shorter hospital lengths of stay. High spatial and contrast resolution 3D CT angiography images are used to plan the procedures and inform device selection and manufacture, but in standard care, the surgery is performed using image-guidance from 2D X-ray fluoroscopy with injection of nephrotoxic contrast material to visualise the blood vessels. This study aims to assess the benefit to patients, practitioners, and the health service of a novel image fusion medical device (Cydar EV), which allows this high-resolution 3D information to be available to operators at the time of surgery. METHODS: The trial is a multi-centre, open label, two-armed randomised controlled clinical trial of 340 patient, randomised 1:1 to either standard treatment in endovascular aneurysm repair or treatment using Cydar EV, a CE-marked medical device comprising of cloud computing, augmented intelligence, and computer vision. The primary outcome is procedural time, with secondary outcomes of procedural efficiency, technical effectiveness, patient outcomes, and cost-effectiveness. Patients with a clinical diagnosis of AAA or TAAA suitable for endovascular repair and able to provide written informed consent will be invited to participate. DISCUSSION: This trial is the first randomised controlled trial evaluating advanced image fusion technology in endovascular aortic surgery and is well placed to evaluate the effect of this technology on patient outcomes and cost to the NHS. TRIAL REGISTRATION: ISRCTN13832085. Dec. 3, 2021.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Análise Custo-Benefício , Computação em Nuvem , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
13.
JMIR Public Health Surveill ; 10: e45379, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38446543

RESUMO

BACKGROUND: Health care authorities often use text messages to enhance compliance with medical recommendations. The effectiveness of different message framings has been studied extensively over the past 3 decades. Recently, health care providers have begun using digital media platforms to disseminate health-related messages. OBJECTIVE: This study aimed to examine the effectiveness of some of the most widely used message framings on the uptake rates of medical checkups. METHODS: This study used a large-scale digital outreach campaign conducted by Maccabi Healthcare Services (MHS) during 2020-2021, involving a total of 113,048 participants. MHS members aged 50-74 years were invited to take their recommended medical actions from the following list: human papillomavirus (HPV), mammography, abdominal aortic aneurysm, fecal occult blood test (FOBT), and pneumococcal vaccination. Each member was randomly assigned to receive 1 of 6 message framings: control (neutrally framed; n=20,959, 18.5%), gains (benefits of compliance; n=20,393, 18%), losses (negative consequences of noncompliance; n=15,165, 13.4%), recommendation (a recommendation by an authoritative figure, in this context by a physician; n=20,584, 18.2%), implementation intentions (linking potential outcomes to future reactions; n=20,701, 18.3%), and empowerment (emphasizing personal responsibility for maintaining good health; n=15,246, 13.5%). The time frames for measuring a successful intervention were 14 days for scheduling screenings (ie, HPV, mammography, or abdominal aortic aneurysm), 30 days for performing the FOBT, and 60 days for receiving pneumococcal vaccination. We also examined the effectiveness of media channels (text message or email) on uptake rates and whether the subject-line length is correlated with message-opening rates. RESULTS: No significant effect of message framing on uptake rates of medical checkups was observed. The rates of appointments for screening ranged from 12.9% to 14.1% across treatments. Based on a chi-square test, there was no evidence to reject the null hypothesis that these compliance rates are independent of the treatments (P=.35). The uptake rates for the FOBT and pneumococcal vaccination ranged from 23.3% to 23.8% across treatments, and we could not reject the hypothesis that they are independent of the treatments (P=.88). We also found that emails are more effective than text messages (P<.001) and that the subject-line length is negatively correlated with message-opening rates. CONCLUSIONS: No evidence was found for an effect of the 5 message framings on uptake rates of medical checkups. To enhance compliance rates, public health officials may consider alternative framings. Furthermore, media channels and the subject-line length should be given careful consideration in the planning stages of health care campaigns. TRIAL REGISTRATION: AEA RCT Registry AEARCTR-0006317; https://www.socialscienceregistry.org/trials/6317/history/201365.


Assuntos
Aneurisma da Aorta Abdominal , Infecções por Papillomavirus , Envio de Mensagens de Texto , Humanos , Instalações de Saúde , Internet , Pessoa de Meia-Idade , Idoso
14.
Biosensors (Basel) ; 14(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38534256

RESUMO

A proof-of-concept of a microwave imaging system for the fast detection of abdominal aortic aneurysms is shown. This experimental technology seeks to overcome the factors hampering the fast screening for these aneurysms with the usual equipment, such as high cost, long-time operation or hazardous exposure to chemical substances. The hardware system is composed of 16 twin antennas mastered by a microcontroller through a switching network, which connects the antennas to the measurement instrument for sequential measurement. The software system is run by a computer, mastering the whole system, automatizing the measurement process and running the signal processing and medical image generation algorithms. Two image generation algorithms are tested: Delay-and-Sum (DAS) and Improved Delay-and-Sum (IDAS). Own-modified versions of these algorithms adapted to the requirements of our system are proposed. The system is carefully calibrated and fine-tuned with known objects placed at known distances. An experimental proof-of-concept is shown with a human torso phantom, including an aorta phantom and an aneurysm phantom placed in different positions. The results show good imaging capabilities with the potential for detecting and locating possible abdominal aortic aneurysms and reporting acceptable errors.


Assuntos
Aneurisma da Aorta Abdominal , Imageamento de Micro-Ondas , Humanos , Aneurisma da Aorta Abdominal/diagnóstico , Software , Algoritmos , Imagens de Fantasmas
15.
Turk Kardiyol Dern Ars ; 52(2): 88-95, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38465530

RESUMO

OBJECTIVE: Aortic rupture is a rare and catastrophic emergency. Prompt diagnosis and treatment are the primary determinants of mortality. During follow-up, the majority of patients who have been effectively treated die from hypovolemic shock and multiorgan failure. This article describes the clinical and procedural details of sixteen patients with ruptured aortic aneurysms treated endovascularly. In addition, it discusses the main factors contributing to the mortality of these patients. METHOD: Patients who underwent endovascular treatment for acute aortic rupture at our center from October 2016 to March 2023 were included in this retrospective study. RESULTS: A total of 16 patients underwent endovascular aneurysm repair (EVAR) or thoracic endovascular aneurysm repair (TEVAR) for acute aortic rupture. The patients' mean age was 73.06 years (range: 52-92), and 15 of them were male. The ruptures occurred in the abdominal aortic aneurysm in ten patients, in thoracic aortic aneurysm in three patients, in the isolated iliac artery aneurysm in two patients, and there was one case of non-aneurysmal aortic rupture. In our series, patients who presented with an impending, self-limited rupture and stable hemodynamic status had good prognostic outcomes. However, eight patients died due to multiorgan failure, hemorrhagic shock, disseminated intravascular coagulopathy, renal failure, or abdominal compartment syndrome. These patients generally had poor admission vital signs and low hemoglobin values. The most critical determinants for the success of the procedure are promptly stopping the bleeding, avoiding general anesthesia, and opting for blood product replacement instead of fluid replacement. CONCLUSION: Each patient with ruptured aortic aneurysm should be managed according to the patient's hemodynamics at presentation, the size of the aneurysm, the suitability for percutaneous procedure, logistical factors, and the operator-center's experience.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Feminino , Humanos , Masculino , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais
16.
Cardiovasc Toxicol ; 24(3): 302-320, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453799

RESUMO

Abdominal aortic aneurysm (AAA) is a chronic vascular degenerative disease. Vascular smooth muscle cells (VSMCs) are essential for maintaining the integrity of healthy blood vessels. Macrophages play an important role in the inflammatory process of AAA. However, the effect of macrophage-derived exosome LncRNA PVT1 on VSMCs is unclear. Exosomes from M1 macrophages (M1φ-exos) were isolated and identified. The expression of LncRNA PVT1 in M1φ-exos was determined. AAA cell model was constructed by treating VSMCs with Ang-II. AAA cell model was treated with M1φ exosomes transfected with si-LncRNA PVT1 (M1φsi-LncRNA PVT1-exo). VSMCs were transfected with miR-186-5p mimic and oe-HMGB1. Cell viability was detected by CCK-8. The accumulation of LDH was detected by ELISA. Western blot was used to detect the expression of HMGB1, inflammatory factors (IL-6, TNF-α and IL-1ß) and pyroptosis-related proteins (GSDMD, N-GSDMD, ASC, NLRP3, Caspase-1 and Cleaved-Capase-1). Cell pyroptosis rate was detected by flow cytometry. At the same time, the targeting relationship between miR-186-5p and LncRNA PVT1 and HMGB1 was verified by double fluorescein experiment. Exosomes from M1φ were successfully extracted. The expression of LncRNA PVT1 in M1φ-exos was significantly increased. M1φ-exo promotes inflammation and pyroptosis of VSMCs. M1φsi-LncRNA PVT1-exos inhibited the inflammation and pyroptosis of VSMCs. LncRNA PVT1 can sponge miR-186-5p mimic to regulate HMGB1 expression. MiR-186-5p mimic further inhibited inflammation and pyroptosis induced by M1φsi-LncRNA PVT1-exos. However, oe-HMGB1 could inhibit the reversal effect of miR-186-5p mimic. LncRNA PVT1 in exosomes secreted by M1φ can regulate HMGB1 by acting as ceRNA on sponge miR-186-5p, thereby promoting cell inflammatory and pyroptosis and accelerating AAA progression.


Assuntos
Aneurisma da Aorta Abdominal , Exossomos , Proteína HMGB1 , MicroRNAs , RNA Longo não Codificante , Humanos , Músculo Liso Vascular , Piroptose , Inflamação , Macrófagos
17.
Vasc Med ; 29(2): 189-199, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38457311

RESUMO

INTRODUCTION: Abdominal aortic aneurysm (AAA) is a relevant clinical problem due to the risk of rupture of progressively dilated infrarenal aorta. It is characterized by degradation of elastic fibers, extracellular matrix, and inflammation of the arterial wall. Though neutrophil infiltration is a known feature of AAA, markers of neutrophil activation are scarcely analyzed; hence, the main objective of this study. METHODS: Plasma levels of main neutrophil activation markers were quantified in patients with AAA and a double control group (CTL) formed by healthy volunteers (HV) and patients with severe atherosclerosis submitted for carotid endarterectomy (CE). Calprotectin, a cytoplasmic neutrophil protein, was quantified, by Western blot, in arterial tissue samples from patients with AAA and organ donors. Colocalization of calprotectin and neutrophil elastase was assessed by immunofluorescence. RESULTS: Plasma calprotectin and IL-6 were both elevated in patients with AAA compared with CTL (p ⩽ 0.0001) and a strong correlation was found between both molecules (p < 0.001). This difference was maintained when comparing with HV and CE for calprotectin but only with HV for IL-6. Calprotectin was also elevated in arterial tissue samples from patients with AAA compared with organ donors (p < 0.0001), and colocalized with neutrophils in the arterial wall. CONCLUSIONS: Circulating calprotectin could be a specific AAA marker and a potential therapeutical target. Calprotectin is related to inflammation and neutrophil activation in arterial wall and independent of other atherosclerotic events.


Assuntos
Aneurisma da Aorta Abdominal , Complexo Antígeno L1 Leucocitário , Humanos , Projetos Piloto , Complexo Antígeno L1 Leucocitário/metabolismo , Interleucina-6/metabolismo , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/cirurgia , Aorta Abdominal/cirurgia , Inflamação
18.
Ultrasonics ; 139: 107284, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458061

RESUMO

High frame rate ultrasound (US) imaging techniques in 3D are promising tools for capturing abdominal aortic aneurysms (AAAs) over time, however, with the limited number of channel-to-element connections current footprints are small, which limits the field of view. Moreover, the maximal steering angle of the ultrasound beams in transmit and the maximal receptance angle in receive are insufficient for capturing the curvy shape of the AAA. Therefore, an approach is needed towards large arrays. In this study, high frame rate bistatic 3D US data (17 Hz) were acquired with two synchronized matrix arrays positioned at different locations (multi-aperture imaging) using a translation stage to simulate what a larger array with limited channel-to-element connections can potentially achieve. Acquisitions were performed along an AAA shaped phantom with different probe tilting angles (0 up to ± 30°). The performance of different multi-aperture configurations was quantified using the generalized contrast-to-noise ratio of the wall and lumen (gCNR). Furthermore, a parametric model of the multi-aperture system was used to estimate in which AAA wall regions the contrast is expected to be high. This was evaluated for AAAs with increasing diameters and curvature. With an eight-aperture 0° probe angle configuration a 69 % increase in field of view was measured in the longitudinal direction compared to the field of view of a single aperture configuration. When increasing the number of apertures from two to eight, the gCNR improved for the upper wall and lower wall by 35 % and 13 % (monostatic) and by 36 % and 13 % (bistatic). Contrast improvements up to 22 % (upper wall) and 12 % (lower wall) are achieved with tilted probe configurations compared to non-tilted configurations. Moreover, with bistatic imaging with tilted probe configurations gCNR improvements up to 4 % (upper wall) and 7 % (lower wall) are achieved compared to monostatic imaging. Furthermore, imaging with a larger inter-probe distance improved the gCNR for a ± 15° probe angle configuration. The gCNR has an expected pattern over time, where the contrast is lower when there is more wall motion (systole) and higher when motion is reduced (diastole). Furthermore, a higher frame rate (45 Hz) yields a lower gCNR, because fewer compound angles are used. The results of the parametric model suggest that a flat array is suitable for imaging AAA shapes with limited curvature, but that it is not suitable for imaging larger AAA shapes with more curvature. According to the model, tilted multi-aperture configurations combined with bistatic imaging can achieve a larger region with high contrast compared to non-tilted configurations. The findings of the model are in agreement with experimental findings. To conclude, this study demonstrates the vast improvements in field of view and AAA wall visibility that a large, sparsely populated 3D array can potentially achieve when imaging AAAs compared to single or dual aperture imaging. In the future, larger arrays, less thermal noise, more steering, and more channel-to-element connections combined with carefully chosen orientations of (sub-) apertures will likely advance 3D imaging of AAAs.


Assuntos
Aneurisma da Aorta Abdominal , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ultrassonografia/métodos
19.
J Cardiothorac Surg ; 19(1): 134, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491494

RESUMO

BACKGROUND: Morphologically, the risk of aortic aneurysm rupture is mainly evaluated based on its type (e.g., fusiform or saccular) and diameter. Based on the finite element analysis, peak wall stress has been identified as a more sensitive and specific predictor of rupture in recent years. Moreover, in finite analysis, the neck of aneurysm is the highest peak wall stress and is associated with the rupture point. CASE PRESENTATION: A saccular aortic aneurysm (84 mm) was incidentally detected during preoperative examination for chronic empyema in a 74-year-old male patient with a history of polycythemia. Aortic arch graft replacement using an open stent was performed. CONCLUSIONS: Morphologically, this case was associated with a very high risk of rupture; nevertheless, it did not rupture. In this case, a mural thrombus (likely formed due to polycythemia) covered the neck of aneurysm that is experiencing the highest peak wall stress and is associated with the rupture point. The mural thrombus decreased peak wall stress and could reduce the risk of rupture even for huge saccular aneurysms. Furthermore, the mural thrombus was fully occupied in aneurysms, such as during coil embolization. Thus, polycythemia could decrease the risk of rupture of huge saccular aneurysms.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Aórtico , Ruptura Aórtica , Policitemia , Tromboembolia , Trombose , Masculino , Humanos , Idoso , Policitemia/complicações , Aneurisma Aórtico/complicações , Ruptura Aórtica/complicações , Trombose/complicações , Trombose/cirurgia , Tromboembolia/complicações , Aneurisma da Aorta Abdominal/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...